相关文章
Related articles联系电话:0531-86127712
18.01.0059 FLAI-SP Bg71风机
G&D/ Guntermann & Drunck GmbH DVIMUX2-DL-USB
G&D/ Guntermann & Drunck GmbH A2100093 DVIMUX2-DL-USB
G&D/ Guntermann & Drunck GmbH A6100125 CPU-DVID-DL-U-2 Connector cable for DVID (dual-link)
STORK TRONIC ST710-PWHVM26 25V-2*0.5)A
FSG SL3002-PK1023/GS80/0101-328.149
SIERRA M100L-DD-2-OV1-PV2-V1-SFC19.3151E-CRWI
SIERRA M100M1-NR-3-OV1-PV2-V1-SFC19.3151E-CRWI
SIERRA 824S-L-2-OV1-PV2-V4-SFC19.3151E-CRWI
Karl Klein DNG 3-6/TS WS
saia-burgess V9N
DINA DNSFT1
DINA DNSFT2
DEUBLIN 1109-040-188
MOOG HEN 228 Art.79802028
WISTRO FLAI BG 112TYP:B31 1L -2 -2
ROSEMOUNT 2120-D-1D-S-1-NA-S-C-U1
YOKOGAWA Y/TC-E22/SPS2/CAL-M
YOKOGAWA Y/TC-E33/SPS23
PHONIX Magnodul type 745.20H/D-1050 IP67
SETTIMA GR60 SMT16B 500L G RF2-Y-160M-4-11KW
SETTIMA GR60 SMT16B 440L G RF2-Y-132M-4-7.5KW
意大利SETTIMA GR25-SMT-25L-SN
GSR G01200004-A52451004.012XX 24V G1/4
GSR GO11O2052-A52421002.012XX 24V G1/4
风机是依靠输入的机械能,提高气体压力并排送气体的机械,它是一种从动的流体机械。风机是中国对气体压缩和气体输送机械的习惯简称,通常所说的风机包括通风机,鼓风机,风力发电机。
风机广泛用于工厂、矿井、隧道、冷却塔、车辆、船舶和建筑物的通风、排尘和冷却,锅炉和工业炉窑的通风和引风;空气调节设备和家用电器设备中的冷却和通风;谷物的烘干和选送,风洞风源和气垫船的充气和推进等 [1] 。
气体压缩和气体输送机械是把旋转的机械能转换为气体压力能和动能,并将气体输送出去的机械。
风机的主要结构部件是叶轮、机壳、进风口、支架、电机、皮带轮、联轴器、消音器、传动件(轴承)等。
风机的轴承温度正常时为≤70℃,如果一旦升高到70℃,有电控的应(会)报警。此时应查找原因,首先检查冷却水是否正常?轴承油位是否正常?如果一时找不到原因,轴承温度迅速上升到90℃,有电控的应(会)再次发出报警、停车信号 [4] 。
风机开车、停车或运转过程中,如发现不正常现象应立即进行检查,检查发现的小故障应及时查明原因设法消除。如发现大故障(如风机剧烈振动、撞击、轴承温度升剧烈上升等)应立即停车进行检查。
风机*运行一个月后,应重新更新更换润滑油(或脂)。以后除每次拆修后应更换外,正常情况下1~2月更换一次润滑油(或脂),也可根据实际情况更换润滑油(或脂)。
(2)用轴承振幅显示时为以下值:
电机同步转速为3000转/分时: 大允许值为:0.1mm(双振幅)
电机同步转速为1500转/分时: 大允许值为:0.2mm(双振幅)
电机同步转速为1000转/分时: 大允许值为:0.31mm(双振幅)
电机同步转速为750转/分时: 大允许值为:0.4mm(双振幅)
电机同步转速为600转/分时: 大允许值为:0.5mm(双振幅)
电机同步转速为500转/分时: 大允许值为:0.6mm(双振幅)
18.01.0059 FLAI-SP Bg71风机