7ML1201-1EF00液位计
KP30.61-06S6-ZMEB/MDC-45-HSC-GS/
PLP20.20-L**/MA-N7-S-AV
KP30.61-06S6-ZMEB/MDC-45-HSC-GS/
PLP20.20-L**/MA-N7-D-AV
KP30.51-A8K9-LMD/MC-N-CSC/PLP20.16-L**/OC-N7-L101 D(ANF3)(CN)(VNR01)
KP40.73-06S8-LMF/ME-CSL/30.27-
LGE/GD-CSL/30.27-LGE/GD-CSC D-VNR01
KP30.24-A8K9-LMD/MB-45-HSC/
PLP20.11,2-LOC-N7 D/FS-L
KP30.31-A8K9-LMD/MB-45-HSC/
PLP20.16-LOC-N7 D/FS-L
KP30.43-06S8-LMF/MC-M5-BSL/30.31
-GD/GE-BSH-W-N-LN-80G-D*-C3(220)
-D/FS VNR01
KP30.41-05S6-LMF/OD-BSL/30.24-BSH/
OB/OC/X-N-LN-80E-D*-C3
(140)-M5-D QW(VNR01)
KP30.24-A8K9-LMD/MB-45-HSC/
PHP20.20-LMB-N7 D/FS-L-VNR01
PLD10/2/CS-GD/4-GC/4-GC/VPEF160
PLD10/3/CS-GD/4-GC/4-GC/4-GC/VPEF120
PLD20/2/CS-GE/25-GD/CI-GE/25-GD/
CD-GE/VPEF180
PLD20/3/CS-GE/11.2-GD/11.2-GD/11.2-GD
PLD20/4/CS-GE/6,3-GD/6,3-GD/6,3-GD/
6,3-GD/VPEF-150
KP30.51S0-06S6-ZMF/MD-N-CSC
PLP20.4.1S0-03S1-LOC/OC-N
PLM20.11,2R0-82E2-LGD/GD-N-EL
PLP20.25D0-03S1-LEB/EA-N
在容器中液体介质的高低叫做液位,测量液位的仪表叫液位计。液位计为物位仪表的一种。
一、概述 UHZ-25型磁浮子液位计和UHZ-27型顶装浮球液位计,可配置远传液位变送器,用以实现液位信号远传的数/模显示。
二、结构原理 MY型属模拟式液位变送器,由液位传感器和信号转换器两部分组成。液位传感器由装在φ20不锈钢护管内的若干干簧管和若干电阻构成,护管紧固在测量管(主体管)外侧;信号转换器由电子模块组成,安置在传感器顶端或底端的防爆接线盒内三、主要技术参数1、量程:由测量范围H确定; 2、误差:±10mm; 3、输出信号:4~20mA.DC(两线制); 4、负载电阻:≤550Ω; 5、供电电压:24V.DC; 6、出线口:M20×1.5(内); 7、环境温度:-40~+60℃; 8、防爆等级:dⅡBT1-4; 9、外壳防护等级:IP65。
主要有流量和扬程,此外还有轴功率、转速和必需汽蚀余量。流量是指单位时间内通过泵出口输出的液体量,一般采用体积流量;扬程是单位重量输送液体从泵入口至出口的能量增量 ,对于容积式泵,能量增量主要体在压力能增加上,所以通常以压力增量代替扬程来表示。泵的效率不是一个独立性能参数,它可以由别的性能参数例如流量、扬程和轴功率按公式计算求得。反之,已知流量、扬程和效率,也可求出轴功率。
三、磁浮球液位计特点变送器是从传感器发展而来的,凡是能输出标准信号的传感器。标准信号是指物理量的形式和数量范围都符合标准的信号。由于直流信号具有不受线路中电感、电容及负载性质的影响,不存在相移问题等优点,所以电工委员会(IEC)将电流信号 4mA~20mA(DC)和电压信号 1V~5V(DC)确定为过程控制系统中模拟信号的统一标准。 [1]
磁浮球液位计具有结构简单、使用方便、性能稳定、使用寿命长、便于安装维护等优点。
四、磁浮球液位计的应用
主要广泛运用于石油加工、食品加工、化工、水处理、制药、电力、造纸、冶金、船舶和锅炉等领域中的液位测量
液位计的类型有音叉振动式、磁浮式、压力式、超声波、声呐波,磁翻板、雷达等。